FDA Design Controls and Software Validation (21 CFR 820.30)
Purpose
Map 21 CFR Part 820 Subpart C — Design Controls to software lifecycle work: design planning, inputs, outputs, review, verification, validation, transfer, and DHF/DMR links, including how software validation (intended use / risk controls) complements verification (requirements and specs). Includes a concise ISO 13485:2016 slice where it overlaps QMS expectations for design and risk (interpretation; align with your notified-body MDSAP scope for EU).
When to Apply
- Defining or updating design procedures, DHF artifacts, or release records for US market devices.
- Interpreting “validation” vs “verification” for software in FDA QMS language.
- Connecting IEC 62304 deliverables to 820.30 design control records.
- Preparing for ISO 13485 audits that reference design control (Clause 7.3).
Requirements (testable)
- Design Plan: Establish and maintain a design and development plan per 820.30(b); scope, responsibilities, interfaces, and review gates; update when software scope or class changes. Rationale: controlled design process.
- Design Inputs: Capture physical and performance requirements from intended use and safety/risk; trace to 820.30(c) records. Software inputs include functional, safety, security, usability, and regulatory constraints. Rationale: correct inputs drive correct outputs.
- Design Outputs: Document 820.30(d) outputs (specs, code baselines, build artifacts) that meet design inputs; include acceptance criteria for verification. Rationale: objective evidence of “what was built.”
- Design Review: Hold 820.30(e) reviews at planned stages; record participants, decisions, and action items for software architecture and major changes. Rationale: defect prevention.
- Design Verification: Demonstrate 820.30(f) that design outputs meet design inputs (tests, analysis, inspection). Map to unit/integration/system tests and static analysis. Rationale: “did we build it right?”
- Design Validation: Demonstrate 820.30(g) that approved device meets user needs and intended use under simulated or actual use as appropriate; include risk-related use scenarios. For software, often clinical/ summative usability and end-to-end clinical workflows where applicable. Rationale: “did we build the right thing?”
- Design Transfer: Ensure 820.30(h) transfer to manufacturing / deployment (including cloud release procedures) with verified procedures and training. Rationale: reproducible release.
- Design History File (DHF): Maintain 820.30(j) compilation of records for each design or type; link to SDD, tests, reviews, risk file, and change records. Rationale: audit trail.
- Device Master Record (DMR): Where applicable, ensure 820.181 DMR entries for released software (labels, IFU, build IDs) are consistent with validated design. Rationale: correct field configuration.
- ISO 13485 alignment (slice): Where QMS is ISO 13485-certified, map 7.3 Design and development and 4.1.6 (software used in QMS) to your procedures; document software validation for GMP/QMS tools per FDA Computer Software Assurance guidance when those tools affect production/quality records. Rationale: single coherent QMS story.
Recommended Practices
- Maintain a one-page 820.30 ↔ IEC 62304 mapping table (SDP ↔ design plan, SOUP ↔ design input/output, etc.).
- Separate verification matrix (REQ→test) from validation summary (intended use / risk / use scenarios).
- Baseline software build IDs in DHF per release.
Patterns
DHF index entry (YAML):
dhf:
device: "Pump-Controller-SW"
design_plan_ref: "DOC-DSP-001 rev C"
inputs_ref: ["REQ-SYS-001", "RMF-2026"]
outputs_ref: ["SAD-001", "SDD-002", "tag: v2.3.1"]
verification:
summary: "reports/VV-REPORT-2.3.1.pdf"
matrix: "trace/req-test-matrix.csv"
validation:
summary: "reports/VAL-SUMMARY-2.3.1.pdf"
note: "Intended use + clinical workflow scenarios; links to IEC 62366 summative tests if UI"
reviews:
- id: "DR-2026-01"
date: "2026-01-04"
attendees: ["SE", "QA", "RA"]
Commit message tying to design controls:
feat: door interlock stop within 50 ms
820.30: design output + verification for REQ-62304-102
DHF: VV-REPORT updated; see TEST-201, TEST-202
Anti-Patterns (risks)
- Calling integration tests “validation” only — risk: missing intended use evidence under 820.30(g).
- DHF references only code without inputs/outputs linkage — risk: 483 observations on incomplete design controls.
- Skipping design transfer for cloud/SaaS deployments — risk: production/tenant config drift.
Verification Checklist
- [ ] Design plan current; reviews documented for major software milestones.
- [ ] Design inputs traceable to risks and intended use; approved.
- [ ] Design outputs (specs, builds) linked to inputs; acceptance criteria defined.
- [ ] Verification evidence (tests, analysis) covers design outputs vs inputs.
- [ ] Validation summary addresses user needs / intended use (not only unit tests).
- [ ] Design transfer records exist for manufacturing/deployment.
- [ ] DHF contains or references required records for the software release.
- [ ] DMR/labeling consistent with released software version.
Traceability
- Tag DHF artifacts with release
vX.Y.Z; linkREQ-*toTEST-*and validationVAL-*orSUM-UE-*(usability). - Map
RISK-CTRL-*to both verification (technical) and validation (use-related) where applicable.
References
- 21 CFR Part 820, Subpart C — Design controls (§820.30).
- 21 CFR Part 820, Subpart M — Records (§820.181 DMR).
- FDA Guidance: “General Principles of Software Validation” (2002) — validation philosophy (interpretation; not superseded for QMS concepts).
- FDA Guidance: “Computer Software Assurance for Production and Quality System Software” (2022).
- ISO 13485:2016, clauses 4.1.6 (software in QMS), 7.3 (design and development), 7.4 (purchasing) as applicable.
- IEC 62304:2006+A1:2015 — software lifecycle (often implemented under design controls).
Changelog
- 1.0.0 (2026-03-20): Initial skill covering 820.30, DHF, verification vs validation, ISO 13485 slice.
Source & license
This open-source skill is cataloged on AgentStack and links to its original source — we do not rehost the code.
- Author: AminAlam
- Source: AminAlam/meddev-agent-skills
- License: MIT
Install and usage instructions live in the source repository linked above.
Reviews
No reviews yet — be the first.
Write a review
Versions
- v0.1.0 Imported from the upstream source.